Commander C200 & C300
0.33 hp – 200 hp (0.25 kW – 132 kW) Normal Duty 0.33 hp – 150 hp (0.25 kW – 110 kW) Heavy Duty 115
V | 208 - 240 V | 380 - 480 V | 575 V | 690 V
Commander variable speed drives have established the standard of excellence in motor control since 1983 when
Control Techniques launched the first world commercial vector drive. Since then, Commander has undergone several successful enhancements, each time bringing new technology and innovations to the world of automation.
The new Commander C series has been designed to be a simple and compact AC motor speed controller that meets advanced requirements for a wide range of applications while optimizing the user experience.
Commander C Highlights
✓ Set just 4 parameters to get your drive started ✓ Plug-in options for advanced control ✓ Dual Safe Torque
Off (STO) ✓ Equipped with the latest energy saving features ✓ Up to 180% overload for high torque applications ✓ On board PLC ✓ Straightforward installation and commissioning ✓ Easy motor pairing and performance control ✓ Robust and reliable design |
|
Simple set up. 3 steps to control
Setting up a drive can require training, specialist knowledge and time.
But Commander C will get you up and running, from out of the box to controlling your motor, in minutes.
Three simple steps will set up your drive for most fan, pump, compressor, conveyor and general purpose applications!
-
Specifications
Control Mode
Open loop vector or V / Hz induction motor control |
✓ |
Open loop Rotor Flux Control for induction motors (RFC-A) |
✓ |
Environment
Ambient Operating Temperature |
Size 1 - 4: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 60°C (140°F) with de-rating Size 5 - 9: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 55°C
(131°F) with de-rating |
Cooling Method |
Forced convection |
Humidity |
95 % non-condensing at 40 °C (104 °F) |
Storage
Temperature |
Size 1 - 4: -40°C to 60°C (-40°F to 140°F) — 24 months Max. Size 5 - 9: -40°C to 55°C (-40°F to 131°F) — 24 months Max. |
Altitude |
De-rate the continuous output current by 1% for every 100 m (328 ft) above 1000 m (3,280 ft) to a maximum of 3000 m (9,840 ft) |
Vibration |
Tested in accordance with IEC 60068-2-64 and IEC 60068-2-6 |
Mechanical Shock |
Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29 |
Enclosure Rating |
IP20, NEMA 1 conduit kits available |
Electromagnetic Capability |
IEC/ EN 61800-3 Immunity and Emissions EN 61000-6-2: Immunity for industrial environments EN 61000-6-4: Emissions for industrial environmentsM/br> EN 61000-3-2:
Harmonic current emissions An EMC data sheet is available on request |
RoHS |
Complies with the Restriction of Hazardous Substances Directive (2011/65/EU) |
AC Supply Requirements
Voltage |
100 V models: 100 to 120 Vac ±10% 200 V models: 200 to 240 Vac
±10% 400 V models: 380 to 480 Vac ±10% 500 V models: 500 to 575 Vac ±10% 690 V models: 500 to 690 Vac ±10% |
Phase |
1Ø and 3Ø (Model dependent) |
Maximum Supply Imbalance |
2% negative phase sequence, 3% voltage imbalance between phases |
Input Frequency |
45 to 66 Hz |
Input Displacement Power Factor |
0.97 |
Control
Switching Frequency |
Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz |
Output Frequency Range |
0 to 550 Hz |
Frequency Accuracy |
±0.02% of full scale |
Frequency Resolution |
0.01 Hz |
Analog Input Resolution |
Voltage mode: 11 bits (unipolar) Current mode: 11 bits |
Braking |
Dynamic braking transistor included, requires external resistor |
Protection
DC Bus Undervoltage Trip |
100 V models: 175 Vdc 200 V models: 175 Vdc 400 V models: 330 Vdc |
DC Bus Overvoltage Trip |
Frame sizes 1 - 4: 100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc |
Frame size 5 - 9: 200V models: 415 Vdc 400 V models: 830 Vdc |
Drive Overload Trip |
Programmable: Default settings: 180% for 3s, 150% for 60s |
Instantaneous Overcurrent Trip |
220% of rated motor current |
Phase Loss Trip |
DC bus ripple threshold exceeded |
Over-temperature Trip |
Drive heatsink temperature exceeds 95°C (203°F) |
Short Circuit Trip |
Protects against output phase-to-phase fault |
Ground Fault Trip |
Protects against output phase-to-ground fault |
Motor Thermal Trip |
Electronically protects the motor from overheating due to loading conditions |
Approval & Listings
UL, cUL |
UL file NMMS/8: E171230 |
CE |
CE approval |
EU |
These products comply with the Restriction of Hazardous Substances Directive (2011/65/EU), the Low Voltage Directive (2014/35/EU) and the Electromagnetic Compatibility Directive, (2014/30/EU). |
RCM |
RCM Registered supplier No. 12003815281 |
ISO |
Manufacturing facilities comply with ISO 9001:2015 and ISO 14001 |
TÜV |
C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a
machine.
Type examination certificates by TÜV Rheinland: Frame sizes 1 - 4: No. 01/205/5383.03/18 Frame sizes 5 - 9: No. 01/205/5387.02/18
Functional safety parameters: EN ISO 13849-1 - Cat 4, PLe EN61800-5-2/EN62061/IEC 61508 - SIL 3
UL functional safety approval: FSPC E171230 |
-
Applications
Whatever your application, Commander C is the perfect solution across industries
The Commander series are simple and compact AC motor speed controllers that meet advanced requirements in a wide range of applications. Their small footprint
– among the smallest in their class – makes them ideal for machine builders and OEMs, where space is at a premium.
|
Pumping, Ventilating & Compressing
-
Improved energy efficiency during periods of low demand
-
On board PLC & PID functionalities make advanced control easy and efficient without the need of an external controller
-
Skip Frequencies allow users to easily avoid equipment resonant frequencies, reducing high vibration levels
-
Supply Loss Ride Through will keep the drive up and running through most power disturbances
|
|
Conveying
-
Accurate remote speed control with fieldbus communications
-
S-ramp acceleration / deceleration profiling provides smooth speed transitions minimizing machine jerk
-
Avoids early wear and tear of the equipment
-
Overload capacity up to 180%
|
|
Lifting, Hoisting & Winching
-
Adjustable mechanical brake sequencing with torque proving function
-
Embedded PLC functionality can manage local I/O reducing the need for an external controller
|
|
Access Control
-
Smooth motion with enhanced open loop control
-
Small physical size allows the drive to be mounted easily in smaller enclosures
-
Highly reliable in harsh environments, providing long lasting service
|
|
Processing (Mixers, Kneaders, Crushers, Agitators, Centrifuges, Extruders)
-
Ease of integration to external PLC or other management systems through networking options
-
Conformal coating for enhanced environmental protection
-
Overload capacity up to 180%
-
Highly stable motor control
|
-
Options
Keypads
|
Remote Keypad RTC
The keypad is remote mountable, allowing flexible mounting on the outside of a panel (meets IP54/NEMA 12). Three line plain text, multi-language LCD keypad for rapid set-up and helpful diagnostics. Battery operated real-time clock allows accurate time
stamping of events, aiding diagnostics. |
|
Remote Keypad
Remote mountable, intuitive plain text, multilingual LCD keypad for rapid set-up and superior diagnostics (using the AI-485 adaptor along with a comms lead). Rapid and secure panel fit with 1 x 32mm hole rated to IP66 (NEMA 4). |
System Integration Modules - Communications
|
SI-PROFIBUS
SI-PROFIBUS interface module enables follower connectivity. It is possible to use multiple SI-PROFIBUS modules or a combination of SI-PROFIBUS and other option module types to add additional functionality such as extended I/O, gateway functionality or
additional PLC features. |
|
SI-DeviceNet
SI-DeviceNet enables follower connectivity. It is possible to use multiple SI-DeviceNet modules to provide additional functionality. |
|
SI-CANopen
Commander C's SI-CANopen interface module supports various profiles, offering optimum flexibility. |
|
SI-Ethernet
SI-Ethernet can be used to provide high speed drive access, global connectivity and integration with IT network technologies. |
|
SI-EtherCAT
SI-EtherCAT allows Commander C general purpose drive to connect and interface with EtherCAT networks. |
|
SI-PROFINET-V2
SI-PROFINET-V2 allows Commander C to communicate and interface with PROFINET PLCs and networks. |
|
SI-Interbus
Interbus interface modules. |
System Integration Modules - Additional I/O
|
SI-I/O
Extended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays. |
Optional Accessories
|
AI-Back-up Adaptor
Port adaptor for SD card parameter cloning, and an input for 24 V back-up. |
|
AI-Smart Adaptor
Has a built-in memory for parameter cloning and an input for 24 V back-up. |
|
AI-485 Adaptor
Adaptor that allows the drive to communicate via RS485. |
|
AI-485 24 V Adaptor
Adaptor with 24 V input. |
|
RS485 Cable
The USB comms cable allows the drive to connect to a PC for use with Commander's PC tools. |
-
Software & Support
Intuitive commissioning software
|
Based on Control Techniques’ 25 years' experience, Connect is our latest drive configuration tool for commissioning, optimizing and monitoring drive/system performance.
|
Advanced machine control
|
Control Techniques' Machine Control Studio provides a flexible and intuitive environment for programming Commander C’s new automation and motion control features.
|
Diagnostics Tool
|
Diagnostic Tool is a fast and simple tool, which allows users of Control Techniques' drives to quickly solve any error codes that the drive may show.
|
Drive Setup
|
Drive Setup
Free access web pages provide ‘how-to’ videos, step by step guides and comprehensive technical manuals for your drive installation. |
|