										DIGITAX STBASE
 | 
										
										DIGITAX STEtherCAT
 | 
										DIGITAX ST INDEXER
 | 
										DIGITAX STEZ MOTION
 | 
										DIGITAX STPLUS
 | 
									
										| Two option module slots | √ | √ | √ | √ | √ | 
									
										| Digital and analogue 
										I/O | √ | √ | √ | √ | √ | 
									
										| Smartcard | √ | √ | √ | √ | √ | 
									
										| High speed freeze input | √ | √ | √ | √ | √ | 
									
										| Safe Torque Off | √ | √ | √ | √ | √ | 
									
										| DC bus paralleling | √ | √ | √ | √ | √ | 
									
										| CT Soft and CTScope 
										commissioning software | √ | √ | √ |  | √ | 
									
										| Removable keypad 
										(optional) | √ | √ | √ | √ | √ | 
									
										| RS485 PC programming 
										port | √ | √ | √ | √ | √ | 
									
										| Intellectual property 
										protection |   |  | √ |   | √ | 
									
										| CTSoft programming |   |  | √ |   | √ | 
									
										| Program multi-tasking |   |  |   | √ | √ | 
									
										| PowerTools Pro 
										programming |   |  |   | √ |   | 
									
										| SyPT Pro programming 
										environment with PLCopen programming |   |  |   |   | √ | 
									
										| Drive-to-drive 
										networking |   |  |   |   | √ | 
								
							 
							* Able to import Index Motion into SyPTPro
							 
							Available motor / drive 
							combinations 
							 
							NB: The selection of drive-motor combinations 
							should be based on duty/load profiles of the 
							application 
							 
							
								
									
										| 
										FUNCTION | 
										QTY | 
										I/O DEFAULT FUNCTION | 
										RATING | 
									
										| Analog input 1 | 1 | Frequency 
										/speed ref 1 | ± 10V | 
									
										| Analog 
										input 2   | 1 | Frequency 
										/speed ref 2 | ± 
										10V(default), 0-20mA or 4-20mA | 
									
										| Analogue 
										input 3 | 1 | Motor 
										thermistor | ± 10V, 
										0-20mA, 4-20mA or Motor thermistor input 
										(default) | 
									
										| Analogue 
										output | 2 | Speed/frequency Torque (active 
										current) | ± 
										10V(default), 0-20mA or 4-20mA | 
									
										| Digital 
										input | 3 | Run reverse 
										input Analogue input 1/2 select Jog forward input | +24V | 
									
										| Digital 
										input / output | 3 | At zero 
										speed output Reset input Run forward input | +24V | 
									
										| Relay | 1 | Drive OK 
										indicator | Normally 
										open | 
									
										| Drive 
										enable (Safe Torque Off) | 1 | Safe Torque 
										Off input | +24V | 
									
										| +24V 
										External input | 1 | External 
										24V supply | +24V | 
								
							 
							
							Drive dimensions  
 
							
								
									
										| 
										DRIVE MODEL RATINGS | 
									
										| 
										MODEL | 
										(V)RATED VOLTAGE
 | 
										NO. OF INPUT PHASES | 
										(ARMS)NOMINAL CURRENT
 | 
										PEAK CURRENT (ARMS)
 | 
									
										| DST1201 | 230 | 1 | 1.1 | 2.2 | 
									
										| DST1202 | 230 | 1 | 2.4 | 4.8 | 
									
										| DST1203 | 230 | 1 | 2.9 | 5.8 | 
									
										| DST1204 | 230 | 1 | 4.7 | 9.4 | 
									
										| DST1201 | 230 | 3 | 1.7 | 5.1 | 
									
										| DST1202 | 230 | 3 | 3.8 | 11.4 | 
									
										| DST1203 | 230 | 3 | 5.4 | 16.2 | 
									
										| DST1204 | 230 | 3 | 7.6 | 22.8 | 
									
										| DST1401 | 400 | 3 | 1.5 | 4.5 | 
									
										| DST1402 | 400 | 3 | 2.7 | 8.1 | 
									
										| DST1403 | 400 | 3 | 4.0 | 12.0 | 
									
										| DST1404 | 400 | 3 | 5.9 | 17.7 | 
									
										| DST1405 | 400 | 3 | 8.0 | 24.0 | 
								
							 
							Note: The drive selection should be based on 
							the duty/load profile of the application
							 
							
								
									
										| 
										SUPPLY REQUIREMENTS | 
									
										| 
										MODEL | 
										SUPPLY VOLTAGE | 
										SUPPLY FREQUENCY RANGE | 
									
										| DST120X | 200V to 
										240V +/-10% single phase | 48Hz to 
										65Hz | 
									
										| DST120X | 200V to 
										240V +/-10% three phase | 48Hz to 
										65Hz | 
									
										| DST140X | 380V to 
										480V +/-10% three phase | 48Hz to 
										65Hz | 
								
							 
							
 
								
									
										| 
										GENERAL DRIVE DATA | 
									
										| 
										TYPE | 
										DETAILS | 
									
										| IP rating | 1P20 (UL Type 1 / NEMA 1) | 
									
										| Weight (net) | 2.1kg (4.6 lb) Excluding keypad and 
										option modules | 
									
										| Ambient operating temperature | 0˚C to 50˚C (32˚F to 122˚F) Output 
										current is derated at ambient 
										temperatures >40˚C (104˚F) | 
									
										| Operating humidity | Maximum relative humidity 95% 
										non-condensing | 
									
										| Altitude | 0m to 3000m (9900ft). Derate the 
										maximum output current for the specified 
										figure by 1% per 100m (330 ft) above 
										1000m (3300 ft). | 
									
										| Power cycles per hour | 60 starts per hour equally spaced | 
									
										| Digital and analogue I/O | 3 dedicated digital inputs 1 Freeze input (1µs)
 1 Standard analogue input (10 bit + 
										sign)
 2 Analogue outputs
 1 High resolution analogue input (16 bit 
										+sign)
 1 Relay output
 3 bi-directional digital input/outputs
 | 
									
										| Vibration | Tested in accordance to 
										IEC60068-2-6/64 | 
									
										| Mechanical shock | Tested in accordance to 
										IEC60068-2-29 | 
									
										| Electromagnetic immunity | Complies with EN61800-3 (2nd 
										Environment) | 
									
										| Electromagnetic emissions | EN61000-6-3 and EN61000-6-4 with 
										optional footprint EMC filter  Complies 
										with EN61800-3 (2nd Environment) with 
										onboard filter. | 
									
										| Safe Torque Off | Category 3  EN 954-1:1997 PLe  EN ISO 13848-1:2006
 SIL 3  EN 61800-5-2:2007
 Approved by BGIA as meeting the 
										requirements of the following standards 
										for the prevention of unexpected 
										starting of the drive:
 |