|
DIGITAX ST
BASE |
DIGITAX ST
EtherCAT |
DIGITAX ST
INDEXER |
DIGITAX ST
EZ MOTION |
DIGITAX ST
PLUS |
Two option module slots |
√ |
√ |
√ |
√ |
√ |
Digital and analogue
I/O |
√ |
√ |
√ |
√ |
√ |
Smartcard |
√ |
√ |
√ |
√ |
√ |
High speed freeze input |
√ |
√ |
√ |
√ |
√ |
Safe Torque Off |
√ |
√ |
√ |
√ |
√ |
DC bus paralleling |
√ |
√ |
√ |
√ |
√ |
CT Soft and CTScope
commissioning software |
√ |
√ |
√ |
|
√ |
Removable keypad
(optional) |
√ |
√ |
√ |
√ |
√ |
RS485 PC programming
port |
√ |
√ |
√ |
√ |
√ |
Intellectual property
protection |
|
|
√ |
|
√ |
CTSoft programming |
|
|
√ |
|
√ |
Program multi-tasking |
|
|
|
√ |
√ |
PowerTools Pro
programming |
|
|
|
√ |
|
SyPT Pro programming
environment with PLCopen programming |
|
|
|
|
√ |
Drive-to-drive
networking |
|
|
|
|
√ |
* Able to import Index Motion into SyPTPro
Available motor / drive
combinations
NB: The selection of drive-motor combinations
should be based on duty/load profiles of the
application
FUNCTION |
QTY |
I/O DEFAULT FUNCTION |
RATING |
Analog input 1 |
1 |
Frequency
/speed ref 1 |
± 10V |
Analog
input 2 |
1 |
Frequency
/speed ref 2 |
±
10V(default), 0-20mA or 4-20mA |
Analogue
input 3 |
1 |
Motor
thermistor |
± 10V,
0-20mA, 4-20mA or Motor thermistor input
(default) |
Analogue
output |
2 |
Speed/frequency Torque (active
current) |
±
10V(default), 0-20mA or 4-20mA |
Digital
input |
3 |
Run reverse
input Analogue input 1/2 select
Jog forward input |
+24V |
Digital
input / output |
3 |
At zero
speed output Reset input
Run forward input |
+24V |
Relay |
1 |
Drive OK
indicator |
Normally
open |
Drive
enable (Safe Torque Off) |
1 |
Safe Torque
Off input |
+24V |
+24V
External input |
1 |
External
24V supply |
+24V |
Drive dimensions
DRIVE MODEL RATINGS |
MODEL |
(V)
RATED VOLTAGE |
NO. OF INPUT PHASES |
(ARMS)
NOMINAL CURRENT |
PEAK CURRENT
(ARMS) |
DST1201 |
230 |
1 |
1.1 |
2.2 |
DST1202 |
230 |
1 |
2.4 |
4.8 |
DST1203 |
230 |
1 |
2.9 |
5.8 |
DST1204 |
230 |
1 |
4.7 |
9.4 |
DST1201 |
230 |
3 |
1.7 |
5.1 |
DST1202 |
230 |
3 |
3.8 |
11.4 |
DST1203 |
230 |
3 |
5.4 |
16.2 |
DST1204 |
230 |
3 |
7.6 |
22.8 |
DST1401 |
400 |
3 |
1.5 |
4.5 |
DST1402 |
400 |
3 |
2.7 |
8.1 |
DST1403 |
400 |
3 |
4.0 |
12.0 |
DST1404 |
400 |
3 |
5.9 |
17.7 |
DST1405 |
400 |
3 |
8.0 |
24.0 |
Note: The drive selection should be based on
the duty/load profile of the application
SUPPLY REQUIREMENTS |
MODEL |
SUPPLY VOLTAGE |
SUPPLY FREQUENCY RANGE |
DST120X |
200V to
240V +/-10% single phase |
48Hz to
65Hz |
DST120X |
200V to
240V +/-10% three phase |
48Hz to
65Hz |
DST140X |
380V to
480V +/-10% three phase |
48Hz to
65Hz |
GENERAL DRIVE DATA |
TYPE |
DETAILS |
IP rating |
1P20 (UL Type 1 / NEMA 1) |
Weight (net) |
2.1kg (4.6 lb) Excluding keypad and
option modules |
Ambient operating temperature |
0˚C to 50˚C (32˚F to 122˚F) Output
current is derated at ambient
temperatures >40˚C (104˚F) |
Operating humidity |
Maximum relative humidity 95%
non-condensing |
Altitude |
0m to 3000m (9900ft). Derate the
maximum output current for the specified
figure by 1% per 100m (330 ft) above
1000m (3300 ft). |
Power cycles per hour |
60 starts per hour equally spaced |
Digital and analogue I/O |
3 dedicated digital inputs
1 Freeze input (1µs)
1 Standard analogue input (10 bit +
sign)
2 Analogue outputs
1 High resolution analogue input (16 bit
+sign)
1 Relay output
3 bi-directional digital input/outputs |
Vibration |
Tested in accordance to
IEC60068-2-6/64 |
Mechanical shock |
Tested in accordance to
IEC60068-2-29 |
Electromagnetic immunity |
Complies with EN61800-3 (2nd
Environment) |
Electromagnetic emissions |
EN61000-6-3 and EN61000-6-4 with
optional footprint EMC filter Complies
with EN61800-3 (2nd Environment) with
onboard filter. |
Safe Torque Off |
Category 3 EN 954-1:1997
PLe EN ISO 13848-1:2006
SIL 3 EN 61800-5-2:2007
Approved by BGIA as meeting the
requirements of the following standards
for the prevention of unexpected
starting of the drive: |